RadiPac centrifugal fans
for cleanroom technology

Clean air
with energy-efficient RadiPac centrifugal fans

Filter fan units (FFUs) are powerful units consisting of a filter and a fan. They are mainly used in ceiling systems in cleanrooms, e.g., in chip factories, beverage filling or plastic injection molding plants, the pharmaceutical industry, or microstructure technology. Their task is to ensure consistently high air quality while precisely regulating temperature and humidity.

The fans are subject to correspondingly high requirements: They must ensure a high air exchange rate and generate sufficient pressure to overcome the resistance of the filters. In addition, they should be intelligently controllable, easy to network, and very quiet, as strict noise protection conditions often apply in cleanrooms.

ebm‑papst has optimized the RadiPac specifically for use in cleanrooms. It impresses in all areas with top ratings and is also extremely compact—ideal for the confined installation conditions in filter-fan-units.


The advantages of RadiPac
for cleanroom technology at a glance:

Various sizes for all standard air volumes:
580, 1,170, and 2,330 m³/h

Low installation depth of only 190 to 275 mm thanks to external rotor design

High efficiency:
6.6% improvement over conventional metal impellers

DCI function (daisy chain interface) for auto-addressing

Simple system monitoring via MODBUS-RTU interface

6–7 dB quieter than standard commercial models – thus meets strict noise protection requirements

Intelligent FFU control – analog or digital

With the flexible interfaces of RadiPac centrifugal fans,
connection is simple, secure, and fast.

MODBUS / 0-10V combination input for digital or analog control with MODBUS-RTU or potentiometer

For fan units with MODBUS/0–10V, the setpoint source can be changed from 0–10V (factory setting) to MODBUS-RTU. This series can be controlled with both an (analog) 0–10V signal and MODBUS (digital).

  • Speed control with potentiometer or any 0–10V source, e.g., laminar flow controller, possible
  • Remote query of any 0–10V sensor (e.g., pressure) connected to the analog 0–10V input of the fan
  • Speed setting via any MODBUS-RTU master

MODBUS / DCI auto-addressing function for cleanroom

Fans with MODBUS/DCI interface can be addressed via a 15V / 24VDC voltage signal (init pin on pin 8 of the RJ45 plug). Only the unit activated with the Init pin listens to messages sent to slave address 247 and accepts a new MODBUS address written to this address 247 by the master controller.

After a unit has been successfully addressed, its DC relay is switched on and the 15V / 24V init pin is forwarded to the next fan module in the chain.

This fan is now activated via the hardware signal (init pin) and addressing continues as described above.

Your collection for RadiPac in cleanroom technology

Go to ebm‑papst FanScout now and receive suitable product recommendations for your application.

Get to know the basic model in detail

RadiPac M

The RadiPac for cleanrooms is based on the RadiPac M:
You can also benefit from the advantages of our radial fan series in cleanrooms – with metal impeller, hollow profile blades, and energy-efficient EC motors.

EC-Control

EC-Control

EC-Control for the parameterization and monitoring of small cleanrooms

ebm_11_usb_relaisbox_o_S

USB-Relay-Box

USB relay box for digital group control and group alarm display

usb_perspektive_schatten_o_S

USB-RS485

USB RS485 subinterface STIXL from Hjelmslund

IMG_3_freigestellt_o_S

Hand-held terminal from vbk

Hand-held terminal from vbk with ebmBUS and MODBUS support

IMG_2650-3_und_2682_2_o_S

Monitoring and control solution

Monitoring and control solution, wall unit or built-in cabinet device from vbk

ACC8_und_ACF200_o_S

ACF300 Area Controller and ACC8 Room Environmental Controller

ACF300 area controller and ACC8 room environmental controller with BMS connection from AirCare

LAN_Kabel_ret_o_S

Wachendorff / Weintek IoT-Gateway

Wachendorff/Weintek IoT gateway for translating MODBUS-RTU into higher-level (server-based) protocols OPC-UA, MQTT and BACnet IP

RS485-Repeater_o_S

RS485-Repeater

RS485 repeater to expand the number of RS485 devices per RS485 segment

LAN_Kabel_u_Bolt_o_S_k1

Transparent gateway

• Transparent gateway for connection to SPS/DDC devices that only support MODBUS TCP.

All information at a glance

Brochure with technical details:

  • Components and advantages
  • Dimensions and performance data
  • Software solutions and accessories

Contact

Do you have any questions? Then write to us—we will be happy to help you!