AC axial fan - HyBlade

Motor: M4D110-GF

Technical description
Weight 9.8 kg
Motor size 110
Size 500 mm
Rotor surface Painted black
Terminal box material PP plastic
Blade material Press-fitted, painted sheet steel blank, sprayed with PP plastic
Number of blades 5
Airflow direction A
Direction of rotation Clockwise, viewed toward rotor
Degree of protection IP54
Insulation class "F"
Ambient temperature note Occasional start-up between -40°C and -25°C is permissible.|For continuous operation at temperatures below -25°C (e.g. refrigeration applications) we recommend our fan design with special low-temperature bearings.
Moisture (F) / Environmental (H) protection class H2+
Max. permitted ambient temp. for motor (transport/storage) + 80 °C
Min. permitted ambient temp. for motor (transport/storage) - 40 °C
Installation position Shaft horizontal or rotor on top; rotor on bottom on request
Condensation drainage holes On stator side
Mode S1
Motor bearing Ball bearing
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) <= 3,5 mA
Electrical hookup Terminal box
Motor protection Thermal overload protector (TOP) with basic insulation
with cable Axial
Protection class I (with customer connection of protective earth)
Conformity with standards EN 60034-1 (2010); EN 61800-5-1 / CE
Approval VDE / EAC